Always striving toward excellence, TOPTION has developed to be a market-driven and customer-oriented enterprise. We focus on strengthening the capabilities of scientific research and completing service businesses. We have set up a customer service department to better provide customers with prompt services including order tracking notice. thermostatic water bath TOPTION have a group of service professionals who are responsible for answering questions raised by customers through the Internet or phone, tracking the logistics status, and helping customers solve any problem. Whether you'd like to get more info on what, why and how we do, try our new product - Best thermostatic water bath manufacturers, or would like to partner up, we'd love to hear from you.The product is distinguished by long-term stability. It is isolated from environmental effects such as impact, vibration, high temperature, etc.
1. Reactor Systems Autoclaves
2. Pilot Systems
3. Mini Plant Systems
4. Scale up for Operational Development
5. Double wall reactors
6. Advanced-Flow Reactors
7. Distillation Systems
8. Material Testing
9. Combinational Chemistry
10. Semiconductor Industry
11. Vacuum Chambers
1. Working temperatures from -100℃ to +350℃
2. Previously unachievable performance
3. Intelligent temperature control
4. Maximum process stability and reproducibility
5. Adopt plate heat exchanger, Pipeline heating, the fastest heating and cooling rates
6. High cooling power from 0.5 to 1200kW
7. Large temperature range without fluid change
8. Closed system, extend thermal fluid lifetime
9. Incredibly compact
10. 7-inch, 10-inch color TFT touch screen display
11. Comprehensive warning and safety functions
12. Rapid cooling down from high temperature (from 300 ℃)·
13. Use magnetic drive pump, solve the circulation pump leakage.
Model | SUNDI-320 | SUNDI-420W | SUNDI-430W | |
Temperature range °C | -30°C~180°C | -45°C~180°C | -45°C~180°C | |
Control Mode | Feed forward PID + Our special dynamic control calculation, PLC controller | |||
Temp. control | Option: process temperature control or jacket oil temperature control | |||
Temp. difference | Set or control the temperature difference between jacket oil and raw material process | |||
Program Editor | 20 programs, each program can edit 45 steps. | |||
Communication protocol | MODBUS RTU Protocol, RS 485 Interface | |||
Temperature feedback | Heat-conducting medium :PT100 Raw material process:PT100 | |||
Temp. accuracy | ±1°C | ±1°C | ±1°C | |
Heating power | 2kW | 2kW | 3kW | |
Cooling capacity | 180°C | l.5kW | 1.8kW | 3kW |
| 50°C | 1.5kW | 1.8kW | 3kW |
| 0°C | 1.5kW | 1.8kW | 3kW |
| -5°C | 0.9kW | 1.2kW | 2kW |
| -20°C | 0.6kW | 1kW | 1.5kW |
| -35°C | \ | 0.3kW | 0.5kW |
Circulation pump | Max10L/min 0.8bar | Max10L/min 0.8bar | Max20L/min 2bar | |
Compressor | Embraco | Embraco | France | |
Expansion valve | Danfoss | Danfoss | Danfoss | |
Evaporator | KAORI Plate heat exchanger | |||
Operation Panel | 7-inch color touch screen controller,temperature curve record.data export to excel format. | |||
Safety protection | Self-diagnosis function; freezer overload protection; high pressure switch, overload relay, thermal protection device, liquid low level protection, high temperature protection and temperature fault protection. | |||
Closed circulation system | The whole system is full closed circulation,there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running.The system will supplement oil automatically at low temperature. | |||
Refrigerant | R404A | R404A | R404A | |
Connection size | DN-15 or M24*1.5 | DN-15 or M24*1.5 | DN-15 or M24*1.5 | |
Water-cooled type W (cooling water at 20°C) | \ | 450L/H | 550L/H | |
Power | AC 220V 50HZ 2.9kW(max) | AC 220V 50HZ 3.3kW(max) | AC 380V 50HZ 4.5kW(max) | |
Case material | SUS 304 | SUS 304 | SUS 304 | |
Optional | Optional Ethernet interface , configure PC operating software | |||
Optional | Optional outside touch screen display controller (separated),the communication line distance is 10 meter. | |||
Optional power | Optional power 100V 50HZ single-phase, 110V 60HZ single-phase, 230V 60HZ single-phase, 220V 60HZ three-phase, 440V~480V 60HZ three-phase | |||
Note | -10°C~200°C, -25°C~200°C, -25°C~300°C, -45°C~250°C, -50°C~250°C, -60°C~200°C, -60°C~250°C, -70°C~250°C, -80°C~250°C, -90°C~250°C, -100°C~100°C, -90°C~250°C, -25°C~200°C, -40°C~200°C |